Description
Helium Leak Detection System with two vacuum chambers to test refrigeration valves. The system can be used with manual loading / unloading from the front (it is equipped with a push-button and light safety barriers), or with automatic loading / unloading from the rear side, by robot. The testing equipment is easily interchangeable to allow the test of different types of components (more than 50 in the specific case).
Technical Specification
- Product to be tested
- Refrigeration valves
- Test type
- Helium charged – vacuum test
- Productivity
- 160 pz/h
- Reject limit
- 7,0 x 10-6 mbar*L/s corresponding to 1 g/y
- Test pressure (max)
- 60 bar