Description
Helium Leak Detection System with three vacuum chambers to test air conditioning hoses. The two frontal chambers are used to test hoses in large quantities: are with automatic opening and closing and allow to test 4 hoses each cycle, discriminating the possible reject hose. The third chamber is used for hoses of different sizes produced in small quantities; closing and opening are manual and a pipe is tested at each cycle.
Technical Specification
- Product to be tested
- Car air conditioning hoses
- Test type
- Helium charged – vacuum test
- Productivity
- 250 pz/h
- Reject limit
- 2,0 x 10-5 mbar*L/s corresponding to 3 g/y
- Test pressure (max)
- 40 bar