Description
Helium is an expensive gas and in many cases it is convenient to use a recovery systems to achieve significant cost savings. It‘s a independent and totally integrated systems that can handle different control station and allow to recover up to 95% of the helium used for the test. The recovery systems, if connected to the leak testing machines con transmit the purity of recovered helium allowing in this way to the leak testing machines, to recalculate the measured leak as if it were measured with 100% helium.
Details
- Efficiency
- Between tra 85% a 95%
- Flow range R1 model
- from 100/150 nl/min
- Flow range R2 model
- from 200/300 nl/min
- Flow range R3 model
- from 300/450 nl/min
- Helium pressure ”out”
- max 80 bar (adjustable)
- Helium pressure ”in”
- max 1,3 bar absolute
- Helium refilling pressure
- max 6 bar